• Companies
  • Contact
  • Français
  • Search icon
Logo Roctest
    • Products
    • Applications
    • Services
    • Case studies
    • Resources
    • About
      • About Us
      • News
      • Events
      • Careers
      • Contact
Close icon Close icon Logo Roctest
  • Search icon
    • Products
    • Applications
    • Services
    • Case studies
    • Resources
    • About
      • About Us
      • News
      • Events
      • Careers
      • Contact
  • Companies
  • Contact
  • Français
  • Logo linkedin
  • Logo youtube
Home » Case studies » Crack detection test in a concrete beam by distributed strain sensing cables

Crack detection test in a concrete beam by distributed strain sensing cables

Published on September 6 2019
  • Facebook Icon
  • Twitter Icon
  • LinkedIn Icon
  • Email Icon

Smartec in collaboration with Politecnico of Turin has pervormed a series of crack detection tests in concrete beams using different types of distriuted optical fiber cables.

Image Crack detection test in a concrete beam by distributed strain sensing cables

The test consists in loading the beam in two points till reaching its ultimate deformation. The beam has a 30 x 15 cm section with 2ø14mm in the upper side and 2ø18mm in the lower side, length equals to 400cm. We have installed 3 distributed strain cables insidethe beam (SmartProfile and Hydro&Geo) and other 2 below the beam (SMARTProfile and SMARTape).

View Paper: “Crack Detection Using Embedded Fiber-Optic Sensors in Reinforced Concrete Beams”.

Image

A DiTest interrogator has been used, with 50cm of spatial resolution and 25cm of sampling interval. All the cables have been joined in a single loop and the reading unit gives a single frequency profile in which different areas represents different types of cable and positions.

Many smaller cracks occurred, between 0.1mm to 2mm. Crack detection with distributed sensors was reliably possible for cracks of 1mm and above, but we are working on thechniques to detect smaller cracks.

Three beams have benn fabricated and tested to failure. The beams had different reinforcement designs to simulate the formation of single large cracks or multiple smaller crack.

Image

In the following example, the local strain peak due to crack formation is visible for load step 8.

Image

Related Applications

Research

Down arrow
close

Search Roctest

Searching...

Logo Roctest

Developer and Manufacturer of Geotechnical & Structural Instruments and Soil/Rock Testing Equipment

Logo Smartec

Provider of innovative Fiber Optic Solutions for Structural Health Monitoring and Geotechnical Instrumentation

Logo Telemac

Provider of Geotechnical & Structural Instruments
since 1947

Logo Enomfra

Provider of Hydrogeological & Geotechnical Services. Investigations, Monitoring & Testing

Logo Roctest

Developer and Manufacturer of Geotechnical & Structural Instruments and Soil/Rock Testing Equipment

Logo Smartec

Provider of innovative Fiber Optic Solutions for Structural Health Monitoring and Geotechnical Instrumentation

Logo Telemac

Provider of Geotechnical & Structural Instruments
since 1947

Logo Enomfra

Provider of Hydrogeological & Geotechnical Services. Investigations, Monitoring & Testing

Legal
  • Privacy Notice – May 2018
  • Terms and Conditions of Sales
  • Sitemap
Follow us
  • Logo linkedin
  • Logo youtube
Logo Logo